Applied timber self-weight only · red width = force, not pressure · ! unresolved review locations · unflagged ≠ safe
Site west: porch / door · North: P0–P1
Drag to orbit · wheel / pinch to zoom · click a piece
FrameSelectedTemporary
Work in progress Individual wall assembly, exterior siding, weather seals and dimension-dependent animation are still being completed.
Complete
Assembled
Views / zoom
Component schedule
Lengths and inclinations are calculated from the current geometry. Actual fabrication cuts and joints remain VERIFY.
Piece
Group / member
Nominal axis length
Nominal section
Axis inclination
R01 end references
Model vertical bevel
Conditional plan miter
Fabrication status
Architectural plans · line drawings
Same selected assembled model, independent of 3D visibility/explosion. Dimensions are measured mesh extents, not stock sizes or saw settings. Source dimensions and provisional geometry are not independently revalidated here. Ground/bearing heights, material and joint design remain unresolved. TFEC-informed review — not structurally qualified.
Component measurements · actual axial lengths
Axial length is measured along the member axis from its current mesh. X/Y/Z extents are world-axis bounds. These are modeled overall dimensions, not fabrication cut lengths. Cupola outside diameter is 88 in; clear inside diameter is 76 in. Temporary steel thickness, holes, positions and attachment details may be illustrative: these are NOT drilling or steel-fabrication dimensions. Source status is retained in the model notes.
ID
Member
Overall axial length
X extent
Y extent
Z extent
Proposed step-lap joinery
Real proposed mating-cut geometry. Geometry review only—not fabrication approved. This comparison does not change the main model selection. Main plans and self-weight follow that selection; baseline force markers are not applied to proposed geometry.
RafterReceiving timberRemoved woodRestored within original stockContact normals, not forces
Both views use the same local crop and scale. Cut edges at the crop boundary are not new timber cuts. In the section view, lines are actual mesh intersections with the longitudinal center plane. The exploded view lifts only the rafter 6 in for inspection; it is not an assembly instruction.
Chosen parameters and measured geometry
Dimensions are chosen design assumptions, not measurements from the reference image or verified construction details. Areas below are geometric measurements at named sections, not whole-member minimum sections or strength checks. The complete contact and neighbor audit remains in the JSON download.
Parameter or result
Value and basis
Limits and unresolved design inputs
The owner-uploaded timber-frame manual has not been read. The independently checked external TFEC reference is not a substitute for that attachment or a professional review.
Comparison downloads are separate from the baseline and named PROPOSED-NOT-FABRICATION.
Cut angles
Angles measured from the selected model's actual planar faces and stock axes. These are geometric angles, not saw settings or a verified manufacturing cut list. Cut depth and joint capacity require separate verification. The full list includes frame and room-layer meshes; components without recorded stock axes show unavailable reference angles.